IV. Troubleshooting

Alarms
The cooling unit has both an audible notification and a visual alarm indicator (shown in
“red” on the control panel) that are activated when an alarm is triggered. Please note:
the temperature alarms (HA and LA) are disabled during the first 23 hours of operation
after the cooling unit is plugged in and/or turned on.

The control panel also will flash a code for each alarm, as follows:

Alarm

What it means

What to do

P1

Probe 1, which senses the
temperature inside the cellar
and controls the on/off cycles
of the cooling unit, has failed

The cooling unit enters a timed
auto- cycle mode until Probe 1 is
repaired or replaced. In this
mode, the cooling unit will turn on
for 12 minutes and off for 8
minutes.

Please call CellarPro at
877.726.8496 to repair or replace
Probe 1

HA

The temperature inside the
cellar is too warm (above
70°F for more than 1 hour)

Check if the cellar has a leak
Check if door was left open
Lower the ambient temperatures

LA The

temperature of the cellar

is too cold
(below 45°F)

Raise the Minimum Set Point to
60°F

Raise the ambient temperature

HA2

The temperature of the
condenser is too high (above
140°F)

Raise the Minimum Set Point

Increase the FON setting

LA2

The ambient temperature at
the condenser coil is too cold

Contact CellarPro at
877.726.8496