Bottle Probe Jack (Bottle Probe): A bottle probe is required if the evaporator

(cold side) is ducted. The bottle probe is designed to plug into the face of the cooling
unit and terminate inside the cellar measuring either air or liquid. Disconnecting the
probe will automatically return the control to air temperature. If used to measure air
temperatures, the differential (HY) on the cooling unit should be set to “4”. If used to
measure liquid temperature, the differential should be set to “1”. To change the
differential on the cooling unit, please refer to our “Advanced Operation” instructions
later in this section.

(4)

Power receptacles: Location for power cords to connect. The picture below

shows how to attach the power cords using the screw holes from the panel for the
clamps.