BoonDocker ARCTIC CAT: Non-turbo Control Box 700/800/1000 (V3) User Manual

Page 14

Advertising
background image

BoonDocker – 1585 Hollipark Dr. Idaho Falls, ID 83401 – 208-542-4411 / 877-522-7805

www.boondockers.com – email:

[email protected]

– fax: 208-524-7381

Revised 12-14-07

Page 14 of 19

If box in in N2O:NON (non-adjustable regulator) mode or N2O:FIX (fixed-regulator) mode:

N2OFuel F-Delay

050 000

Descritpion of N2O Fuel menu for NON / FIX mode:

050

N2O fuel setting. Amount is centered at 1000psi, if bottle pressure is lower, actual fuel
delivered will be reduced, if bottle pressure is higher, actual fuel delivered will be higher.

Delay 000

Delay in number of engine cycles from when nitrous is activated to when fuel is
delivered. Use this feature to reduce any bog that occurs due to fuel being delivered
before nitrous arrives in the engine. Start with 000, and only exceed numbers above 10
with extreme caution!

TPS:

To select throttle-position triggering, move the cursor until it is under TPS and press “SEL”, Up or Down

Arrow. The following screen will appear:

TPS N2O on if

OFF TPS > 200

TPS OFF

Shows TPS mode is OFF.

200

TPS threshold value.

Under TPS, press the Up or Down Arrow to toggle the TPS mode ON or OFF.

Move the cursor right to the 200 setting, then use the Up and Down Arrows to select the trigger level. This
number is set to near 200 at the factory. You can adjust it from 50 to 248. To choose your level, look at the
third Stats screen. (Press “SEL” to get to the Main Menu, then select Stats, and press “SEL” until the third
Stats screen appears – “N2O” is displayed in upper left-hand corner). With the engine on a test stand,
quickly press the throttle fully and release it. Note the number under “MxTP” This is the maximum value
your TPS will output. Let the engine idle, clear the Stats screen, and note the MxTP number, which is the
minimum TPS output. Choose a number close to the maximum for full-throttle activation. If you choose a
number too close to the maximum, it may sometimes fail to trigger. If you choose a number too low, it may
trigger when only moderate acceleration is desired.

Press the “SEL” button to return to the Main Menu.

RPM:

To select rpm triggering, move the cursor right until it is under RPM and press “SEL”, Up or Down Arrow.

The following screen will appear:

.

RPM Min Max

OFF 5050 7550

RPM OFF

Shows RPM mode is OFF.

5050

Min RPM threshold

7550

Max RPM threshold

Under RPM, press the up or down button to turn this mode ON or OFF.

Move the cursor right to adjust the Minimum RPM (nitrous will be on above this level) and the Maximum
RPM
(nitrous will turn off above this level).
Note: To use this mode, TPS must also be ON and the TPS trigger threshold set.

Press the “SEL” button to return to the Main Menu.


BTN:

To select the button mode, move the cursor right until it is under Btn. Press the up or down key to select

between the following five possible modes. The screen will change to the following:

OFF:

Description: Btn

Button Off :

OFF

This mode disables the handlebar button.

N2O:

Description: Btn

N2O + Fuel :

N2O

Advertising