A.8 Jumper Setting

The jumper settings of the IO1 module depend on the module’s position relative to the
VMP2 and other modules, if any (please see Figure A4 below).

Table A-4: IO1 Jumper Settings for Different Module Positions

IDSEL

Clock

GNT#

REQ#

J12

J11

J10

J1

J2

J3

J4

J5

J6

J7

J8

J9

Position 1

Set

Open

Open

Set

Open

Open

Set

Open

Open

Set

Open

Open

Position 2

Open

Set

Open

Open

Set

Open

Open

Set

Open

Open

Set

Open

Position 3

Open

open

Set

Open

Open

Set

Open

Open

Set

Open

Open

Set





Note:

Position 1 refers to the settings applicable when 1 module (IO1 or
other) is attatched to the VMP2.

Position 2 refers to the settings applicable when 2 modules (IO1
or other) are attatched to the VMP2.

Position 3 refers to the settings applicable when 3 modules (IO1
or other) are attatched to the VMP2.
Important!: Position 3 has not yet been tested and approved by
PEP and is not recommended for use in this issue of the manual.