Kontron AM4024e User Manual

Page 20

Advertising
background image

D R A F T — F O R I N

T E R N A L U S E O N L Y

20

www.kontron.com

User Guide

AM4024(E)

Gener

al

Power Consumption

See Chapter 4 for details.

Temperature Range

Operational: -5°C to +55°C

Standard (depending on processor version and air-
flow in the system)

Storage:

-40°C to +70°C

Without hard disk and without battery

Note:

When the RTC Backup Battery Module is installed, refer to the opera-

tional specifications of this module as this determines the storage tem-
perature of the AM4024(E). (See "RTC Backup Battery Module" below.)

Note:

When additional components are installed, refer to their operational

specifications as this will influence the operational and storage tem-
perature of the AM4024(E).

RTC Backup Battery Mod-
ule (on request)

Special battery mezzanine module with up to two batteries connected in parallel;
uses the J7 connector for interfacing with the AM4024(E)
Temperature ranges:
Operational: - 5°C to + 55°C
Storage:

-30°C to + 60°C

Climatic Humidity

93% RH at 40 °C, non-condensing (acc. to IEC 60068-2-78)

Dimensions

Dimensions of the AM4024(E) without retention screws on front panel:
Mid-size: 181.5 mm x 73.5 mm x 18.96 mm

Board Weight

280 grams
The above-mentioned board weight refers to the AM4024(E) without extension
modules such as the SATA Flash module or the RTC Backup Battery module.

Table 2: AM4024(E) Main Specifications (Continued)

FEATURES

SPECIFICATIONS

Advertising
This manual is related to the following products: