5.1.2 Airflow Paths

The area between the front panel and the AMC Card-edge connector is divided into five zones, one I/O
zone and four uniform thermal zones, A, B, C, and D. The PICMG AMC.0 Specification states that the
uniformity of the airflow paths’ resistance should provide an impedance on the A, B, C, and D zones
that is within ± 25% of the average value of the four thermal zones.

The following figure shows the thermal zones of the AM4024(E).

Figure 15: Thermal Zones of the AM4024(E) Module

Table 38: AM4024(E) Airflow Impedance by Zone [N/m²]

VOLUMETRIC

FLOW RATE [CFM]

PRESSURE DROP [N/m²]

I/O ZONE

ZONE A

ZONE B

ZONE C

ZONE D

5

3.5 3.4 3.4

3.2 2.8

10

9.5 9.0 8.9

8.3 7.2

15

15.7 14.9 14.6 13.8 11.9

20

24.7

22.7

22.4 21.0 18.0

25

34.5 31.2 30.8

29.3

25.2

30

46.4 42.4

41.4 39.1 33.7

35

60.4 54.1 53.1 50.4 42.8

40

75.2 67.2

65.8 62.5 53.1

Table 39: AM4024(E) Airflow Impedance by Zone [inches H

2

O]

VOLUMETRIC

FLOW RATE [CFM]

PRESSURE DROP [inches H

2

O]

I/O ZONE

ZONE A

ZONE B

ZONE C

ZONE D

5

0.01

0.01

0.01

0.01

0.01

10

0.04

0.04

0.04

0.03

0.03

15

0.06

0.06

0.06

0.06

0.05

20

0.10

0.09

0.09

0.08

0.07

25

0.14

0.13

0.12

0.12

0.10

30

0.19

0.17

0.17

0.16

0.14

35

0.24

0.22

0.21

0.20

0.17

40

0.30

0.27

0.26

0.25

0.21

I/O ZONE

ZONE A

ZONE B

ZONE C

ZONE D

32.8 mm

34 mm

34 mm

34 mm

34 mm

PCB

component
envelope

component
envelope