1 sensor list, Sensor list – Kontron AM4024e User Manual

Page 84

Advertising
background image

D R A F T — F O R I N

T E R N A L U S E O N L Y

84

www.kontron.com

User Guide

AM4024(E)

10.6.1 Sensor List

The following table indicates all sensors available on the AM4024(E). For further information on Kon-
tron’s OEM specific sensor types and sensor event type codes presented in the following table, refer to
Chapter 10.8, OEM Event/Reading Types.

Table 57: Sensor List

SENSOR NUMBER /

ID STRING

SENSOR TYPE (CODE) /

EVENT/READING TYPE (CODE)

Assertion Mask /

Deassertion Mask/

Reading Mask

DESCRIPTION

Health LED

Shows Error

00h /
A1:IPMI Info-1

OEM Firmware Info 1 (C0h) /
OEM (70h)

0003h / 0000h /
7FFFh

For internal use only

N

01h /
A1:IPMI Info-2

OEM Firmware Info 2 (C0h) /
OEM (71h)

0003h / 0000h /
7FFFh

For internal use only

N

02h /
A1:IPMI Watchdog

Watchdog (23h) /
Sensor-specific (6Fh)

010Fh / 0000h /
010Fh

Watchdog 2

Y

03h /
A1:FRU Agent

OEM (C5h) /
Discrete (0Ah)

0140h / 0000h /
0147h

FRU agent

N

04h /
A1:Health Error

Platform Alert (24h) /
Digital discrete (03h)

0000h / 0000h /
0003h

Aggregate states (power, tem-
perature, etc.). Visualization
by the Health LED.

Y

05h /
A1:MMC Reboot

Platform Alert (24h) /
Digital discrete (03h)

0002h / 0000h /
0003h

MMC reboot active state. Is
asserted during boot time.

N

06h /
A1:Module-
HotSwap

OEM (F2h) /
Sensor-specific (6Fh)

001Fh / 0000h /
001Fh

Hot swap sensor

N

07h /
A1:IPMBL State

OEM (C3h) /
Sensor-specific (6Fh)

0007h / 0000h /
000Fh

State of IPMB-L bus

N

08h /
A1: MMC Stor Err

Mgmt. Subsyst. Health (28h)
/ Sensor-specific (6Fh)

0002h / 0000h /
0003h

Storage error

N

09h /
A1: MMC FwUp

Firmware Upgrade Manager
(C7h) / Sensor specific (6Fh)

010Fh / 0000h /
010Fh

Status of Firmware Upgrade
Manager

N

0Ah /
A1: Ver change

Version Change (2Bh) / Sen-
sor specific (6Fh)

0002h / 0000h /
0002h

MMC firmware upgrade detec-
tion

N

0Ch /
A1:Board Reset

OEM (C4h) /
Sensor-specific (6Fh)

04DEh / 0000h /
04DEh

Board reset event

Y

0Dh /
A1:Temp CPU

Temperature (01h) /
Threshold (01h)

1A81h / 7A81h /
3939h

CPU die temperature

Y

0Eh /
A1:Temp PCH

Temperature (01h) /
Threshold (01h)

0A80h / 7A80h /
3838h

PCH temperature

Y

0Fh /
A1:Temp Air

Temperature (01h) /
Threshold (01h)

7A95h / 7A95h /
3F3Fh

Air temperature near AMC
edge-connector

Y

10h /
A1:Board 3.3vIPM

Voltage (02h) /
Threshold (01h)

2204h / 2204h /
1212h

AMC Management Power (MP)
3.3V

Y

11h /
A1:Board 12.0v

Voltage (02h) /
Threshold (01h)

2204h / 2204h /
1212h

AMC Payload Power (PWR) 12V

Y

Advertising
This manual is related to the following products: