Table 4: connector x1a - row b – Kontron COMe-cPV2(v1.0) User Manual

Page 25

Advertising
background image

Kontron microETXexpress-PV User’s Guide

www.kontron.com

21

Pin

Signal

Description

Type

Terminati

on

Comment

A11

0

GND (Fixed)

Power Ground

PWR

-

-

Table 4: Connector X1A - Row B

Pin

Signal

Description

Type

Terminati

on

Comment

B1

GND (Fixed)

Power Ground

PWR

-

-

B2

GBE0_ACT#

Ethernet Activity

LED

O-

3.3/3.3SUS

-

-

B3

LPC_FRAME#

LPC Frame

Indicator

O-3.3

-

-

B4

LPC_AD0

LPC Address /

Data Bus

I/O-3.3

-

-

B5

LPC_AD1

LPC Address /

Data Bus

I/O-3.3

-

-

B6

LPC_AD2

LPC Address /

Data Bus

I/O-3.3

-

-

B7

LPC_AD3

LPC Address /

Data Bus

I/O-3.3

-

-

B8

LPC_DRQ0#

LPC DMA request

I-3.3

PU 3.3 of

-20K in

the ICH8M

-

B9

LPC_DRQ1#

LPC DMA request

I-3.3

PU 3.3 of

-20K in

the ICH8M

-

B10

LPC_CLK

LPC Clock

O-3.3

-

-

B11

GND (Fixed)

Power Ground

PWR

-

-

B12

PWRBTN#

Power Button

Input

I – 3.3 SUS

Weak

pullup in

the CPLD

-

B13

SMB_CLK

SMBus Clock

I/O-3.3 SUS

PU 3.3

SUS of

2.2K

-

B14

SMB_DAT

SMBus Data

I/O-3.3 SUS

PU 3.3

SUS of

2.2K

-

B15

SMB_ALERT#

SMBus Interrupt

I/O-3.3 SUS

PU 3.3

SUS of

10K

-

B16

SATA1_TX+

SATA 1 Transmit

Data+

DP-O

-

-

B17

SATA1_TX-

SATA 1 Transmit

Data-

-

-

B18

SUS_STAT#

Indicates

imminent suspend

operation; used

to notify LPC

O-3.3 SUS

-

-