Kontron microETXexpress-PV User’s Guide

www.kontron.com

44

stated in the COM.0 specification, rather than the edge triggered SYS_RESET#

provided to the ICH.

This behavior is achieved through a combination of code running in

the CPLD and code in the BIOS. When

SYS_RESET# is kept asserted, a flag is also asserted in the CPLD. When the

BIOS starts, this flag is read and if it's found asserted, the BIOS enters

into a loop, thus preventing the board from booting. When the SYS_RESET# is

de-asserted, the CPLD will de-assert the flag and the BIOS will exit the loop

and issue a final platform reset.

Power Supply

The microETXexpress®-PV-XT COM has a wide range of power input, from 4.75V to

18V DC. The supply voltage is applied through 24 pins (VCC) on the module

connectors.

In general, single supply mode means that the module is able to function with

a single supply (no standby voltage is necessary). All other functions

attributed to the ATX mode remain functional.

WARNING: In ATX mode with 5V standby voltage, the VCC_12V input must be

higher than the standby voltage.

ATX Mode / Single Supply Mode

ATX Mode:

When an ATX power supply is connected, PWR_OK is set to low-level and VCC is

off. Pressing the power button enables the ATX PSU setting PWR_OK to high-

level and powers on VCC. The ATX PSU is controlled by the PS_ON# signal,

which is generated by SUS_S3# via inversion.

Table 14: ATX Mode

State

PWRBTN#

PWR_OK

V5_StdBy

PS_ON#

VCC

S3

x

x

5V

x

0V

S5

high

low

5V

high

0V

S5 -> S0

PWRBTN Event

low -> high

5V

high -> low

0 V-> VCC

S0

high

high

5V

low

VCC

Single Supply (Battery) Mode:

Advertising