Design Considerations

6.1

Thermal Management

6.1.1

Commercial Grade Module (36007-0000-18-2):

A heat spreader plate assembly is available from Kontron Embedded Modules for

the microETXexpress®-PV-XT COM. The heat spreader plate on top of this

assembly is NOT a heat sink. It works as a COM Express®-standard thermal

interface to be used with a heat sink or other cooling device.

External cooling must be provided to maintain the heat spreader plate at

proper operating temperatures. Under worst-case conditions, the cooling

mechanism must maintain an ambient air and heat spreader plate temperature of

60° C or less.

The aluminum slugs and thermal pads on the underside of the heat spreader

assembly implement thermal interfaces between the heat spreader plate and the

major heat-generating components on the microETXexpress®-PV-XT. About 80

percent of the power dissipated within the module is conducted to the heat

spreader plate and can be removed by the cooling solution.

Kontron also has defined a passive heat sink that can be used in place of the

heat spreader plate to provide additional cooling. You can use many thermal-

management solutions with the heat spreader plates, including active and

passive approaches. The optimum cooling solution varies, depending on the COM

Express® application and environmental conditions. Drawings for both the heat

spreader plate and the passive heat sink are available on request. Also, see

the PICMG COM Express® Design Guide on the PICMG website for further

information about thermal management.

6.1.2

Industrial Grade Module (38009-0000-18-2):

The module is designed to operate in an ambient temperature of -40°C up to

+85°C range. Accordingly, special attention needs to be given to design and

install an appropriate thermal solution and provide sufficient airflow the

module.