17 miscellaneous circuits, Miscellaneous circuits, Table 15: single supply mode – Kontron COMe-cPV2(v1.0) User Manual

Page 49: 17 miscellaneous circuits speaker, Battery

Advertising
background image

Kontron microETXexpress-PV User’s Guide

www.kontron.com

45

To enable the single supply mode the BIOS setup must be changed. The “Battery

Mode” must be enabled from the Boot menu. Setting “Power Scheme” option to

“Battery Mode” in the BIOS will enable the following features:

»

The PWR_OK# state is ignored and the input voltage monitoring will be

enabled

An internal voltage monitor will let the board start (after a power

button event or self-power up) when the input voltage is above 4.5V.

The voltage monitor accomplishes this by controlling, via the CPLD, the

BATLOW# signal of the ICH8M. When BATLOW# is asserted the ICH8M will

defer the platform to leave the power states S3 – Suspend to RAM, S4 –

Suspend to disk or S5 – Soft off. Once BATLOW# goes inactive the ICH8M

will let the platform transition to S0.

»

Onboard debug LED will be disabled

The onboard debug LED will be turned off to reduce the power

consumption, especially when not in S0.

Table 15: Single Supply Mode

State

PWRBTN#

PWR_OK

V5_StdBy VCC (4.75-

18V)

Note

S3

x

x

5V

VCC

3

S3 -> S0

PWRBTN

Event

x

x

VCC

S5

x

x

5V

VCC

3

S5 -> S0

PWRBTN

Event

x

x

VCC

NOTES: 1) Columns marked “x” are not relevant for the specified power state.

2) All ground pins have to be tied to the ground plane of the carrier

board.

3) In suspend either V5_StdBy AND/OR VCC can be powered.

4.1.17

Miscellaneous Circuits

Speaker

The implementation of this subsystem complies with the COM Express®

Specification. For additional implementation information, refer to the PICMG

COM Express® Design Guide.