5 system management bus (smbus), 6 k-station / jida32 resources, System management bus (smbus) – Kontron COMe-cPV2(v1.0) User Manual

Page 64: K-station / jida32 resources, Table 25: smbus address assignments, Table 26: i, Table 27: storage, Table 28: gpio

Advertising
background image

Kontron microETXexpress-PV User’s Guide

www.kontron.com

60

A0h

JILI-EEPROM

No

EEPROM for

JILI Data

4

7.5

System Management Bus (SMBus)

Table 25: SMBus Address Assignments

Address Device

Notes

JIDA Bus

Nr

.

12h

SMART_CHARGER

Not to be used with any SMBus device

except a charger

1

14h

SMART_SELECTOR

Not to be used with any SMBus device

except a selector

1

16h

SMART_BATTERY

Not to be used with any SMBus device

except a battery

1

5Ch

ON Semiconductor ADT7476

HWM

Do not use under any circumstances

1

A0h

SPD EEPROM on DDR2

Do not use under any circumstances

1

A2h

SPD EEPROM on DDR2

Do not use under any circumstances

1

D2h

Clock Gen

CK610/ICS9DB403

Do not use under any circumstances

1

7.6

K-Station / JIDA32 Resources

Table 26: I

2

C

Bus

Function

I2C 0

Internal / JIDA I2C #1

I2C 1

SMBus

I2C 2

Internal / JIDA I2C #2 (for

slow devices)

I2C 3

JILI I2C

Table 27: Storage

Device

Function

EEPROM 0

JIDA EEPROM Area 1 with 32 Bytes (free

to use)

Table 28: GPIO

Port

Function

IO-Port 0

GPIO Port, Bit 0-3: Input, Bit 4-7:

Output