Electrical specifications, Mechanical specifications, Environmental specifications – Kontron KISS 2U KTQ87 User Manual

Page 45

Advertising
background image

12. Technical Data

KISS 2U V2 MB_SBC– User's Guide (Version 1.00)

12.1. Electrical Specifications

The corresponding electrical specifications of your KISS 2U V2 platform can be found on the type label.

12.2. Mechanical Specifications

Dimensions

KISS 2U V2 (Standard Version)

Height

2U (88 mm) (3.5”)

Width

Front: 19”; Chassis: 430 mm (16.9")

Depth

Chassis: 472.3 mm (18.6")

Weight
(without packaging)

Aprox. 10.00 kg (22.046 lbs.)

Chassis

Chassis, black (RAL 7021)

Front access panel: blue (RAL 5017)

12.3. Environmental Specifications

Thermal Management

2x system fan (temperature-controlled)
PSU fan
CPU fan

Operating Temperature /
Relative Humidity

0 … +50 °C @5-95 % not condensing [at +55 °C (131 °F) at 10% POH per month]

(32 .. 122 °F @5-95 % not condensing [+55 °C (131 °F) at 10% POH per month]

Storage / Transport
Temperature / Relative
Humidity

-20 … +70 °C @ 5-95 % not condensing
(-4 … 158 °F @ 5-95 %) not condensing

Max. Operation Altitude

2,000 m (6,560 ft)

Max. Storage / Transport
Altitude

10,000 m (32,810 ft)

Operating Shock

15 G, 11 ms, half sine

Storage / Transit Shock

30 G., 11 ms, half sine

Operating Vibration

10 – 500 Hz, 1.0 G

Storage / Transit Vibration

10 – 500 Hz, 2.0 G

Acoustic Noise

< 35 dB(A) (at 1 m in front of the system, full load)
∼ 40 dB(A) for systems with Intel® Quad Core™ processor or redundant PSU

www.kontron.com

43

Advertising