Kontron CG2200 Carrier Grade Server User Manual

Page 74

Advertising
background image


67

Kontron CG2200 Carrier Grade Server Installation and Maintenance Guide

5. Remove the sheet metal fan cage. For instructions, see “Removing the Fan Cage”.

6. Disconnect all of the cables connected to the FP board. See Figure 7 and Table 6 for the cable

routing. For the location of each connector on the FP board, see Figure 48.

Disconnect the multifunction power and signal cable that connects to the fan control board.

Disconnect the SSI front panel board cable that comes from the baseboard.

Disconnect the LED/switch board power and signal ribbon cable.

Disconnect the TAM signal cable.

Disconnect the USB cable that comes from the baseboard

7. Unscrew the two fasteners on the FP board (Figure 49, “A”) and slide the board away from the front

of the chassis and over the two keyhole standoffs (“B”) to lift it up and out of the chassis. (“C”)
Save the screws for reuse with the new replacement FP board.

Figure 49. Removing the Front Panel Board from the Chassis

Advertising