Hard disk power down mode, Suspend timeout (minute), Throttle slow clock ratio – Kontron CP307-V BIOS User Manual

Page 44

Advertising
background image

Advanced Setup

CP307/CP307-V BIOS Guide

Page 34

ID 35978, Rev. 2.0

P R E L I M I N A R Y

Hard Disk Power Down Mode

This function is used to select the state of the hard disk devices if APM power save is requested
by the OS.

Optimal default setting: Suspend
Fail-Safe default setting: Disabled

Suspend Timeout (Minute)

This function specifies the length of time the system waits before it enters suspend mode.

Optimal and Fail-Safe default settings: Disabled

Throttle Slow Clock Ratio

This function is used to select the CPU duty cycle if the system is put into throttling mode via
APM.

Optimal and Fail-Safe default settings: 50.0 %

SETTING

DESCRIPTION

Disabled

Use this setting to inhibit the state change of the hard disk devices.

Suspend

Use this setting to allow the state change of the hard disk devices.

SETTING

DESCRIPTION

Disabled

Use this setting to prevent the system from entering suspend mode.

1 Min
2 Min
4 Min
8 Min

10 Min
20 Min
30 Min
40 Min
50 Min
60 Min

Use one of these settings to specify the computer system’s supspend timeout.

SETTING

DESCRIPTION

87.5 %
75.0 %
62.5 %
50.0 %
37.5 %
25.0 %
12.5 %

Use one of these setting to specify the CPU duty cycle if the system is put into throttling
mode via APM

Advertising
This manual is related to the following products: