INSTALLING FACE CAPS

CUT NHP-6 GASKET 3/4" SHORT

ON BOTTOM SIDE OF HORIZONTAL

FACE CAPS.

WHEN INSTALLING FACE CAPS

USE DEADBLOW HAMMER AND

IMPACT CAPS AT LOCATIONS

OF GLAZING CLIPS ONLY.

INSTALL VERTICAL CAPS

FIRST, THEN HORIZONTALS.

3/4"

NOTE:

SCREWSPLINE SYSTEM

AVAILABLE WITH 1" OR 1/4"

GLAZING. WHEN INSTALLING

1" SYSTEM AND GLAZING 1/4"

GLASS, ADAPTORS WILL BE

REQUIRED. REFERENCE

SHEET #18.

IF 1/4" GLAZING SYSTEM IS

USED REFERENCE SHEET #38

FOR ADDITIONAL INFORMATION.

FACE CAPS:

HP-10437 @ TYPICAL MULLS &

HORIZONTALS

HP-10438 @ PERIMETER

JAMBS, HEAD & SILL

CAP INSTALLATION NOTE:

TO INSTALL FACE CAPS, LOCATE CAP ONTO

CLIPS AT EACH END. PRESS FIRMLY AGAINST

CAP UNTIL GASKET IS COMPRESSED AGAINST

GLASS AND STRIKE AT PREVIOUSLY MARKED

LOCATIONS OF GASKET CLIPS. WHEN INSTALLED

PROPERLY CAPS SHOULD RESIST ROTATION.