PERIMETER SEALANT

PRIMARY WEATHER SEAL

PRIMARY WEATHER SEAL

TOP JAMBS.

AT HEAD AND DOWN 2" AT

SECONDARY WEATHERSEAL

COSMETIC SEAL

COSMETIC SEAL

COSMETIC SEAL

PRIMARY WEATHER SEAL

THE INTERIOR IF NEEDED.

WHILE NOT REQUIRED FOR PROPER SYSTEM PERFORMANCE, THE COSMETIC SEAL MAY BE APPLIED ALONG

WILL GREATLY AFFECT THE PERFORMANCE OF THE SYSTEM.

FAILURE TO APPLY BOTH THE PRIMARY AND SECONDARY WEATHER SEALS IN THE CORRECT LOCATIONS

OF JAMB ONLY. THIS PREVENTS WATER INFILTRATION DIRECTLY INTO THE SYSTEM FROM ABOVE.

THE SECONDARY WEATHER SEAL MUST BE APPLIED AT THE FACE OF THE COVER AT THE HEAD AND TOP 2"

UNIT.

SYSTEM AND IS REQUIRED AT THE JAMBS TO ALLOW PROPER CLEARANCE FOR INSTALLAITON OF FINAL

INSTALLING GLASS AND FACE CAPS. A MINIMUM 3/8" CAULK JOINT IS RECOMMENDED FOR THE HP-1750

FOR EASE OF INSTALLATION IT IS RECOMMENDED THAT THE PRIMARY SEAL BE APPLIED PRIOR TO

ABOVE. THIS IS ESPECIALLY CRITICAL AT THE SILL SO THAT PROPER DRAINAGE OF WATER CAN TAKE PLACE.

THE PRIMARY WEATHER SEAL MUST BE APPLIED ALONG THE HEAD, JAMB AND SILL MEMBERS AS SHOWN

NOTE:

FOR SYSTEM WEEPAGE.

KEEP AREA OPEN AT SILL

NHP-6