SSG - MULLION REINFORCING

HP-10390

HP-10469

HP-10414 REINFORCMENT

ATTACH W/ FS-255

(#12 X 3/4" PFH) @

HEAD & SILL ONLY

POSITION REINFORCEMENT TO

FIT AGAINST WALL OF

MULLION TO PROVIDE MAXIMUM

CLEARANCE FOR MULL FILLER

HP-10390

HP-10434

3/8" X 3 3/4" STEEL

BAR. CUT LENGTH TO BE

MULL LENGTH MINUS 2"

AND INSET 1" FROM EACH

END. ATTACH W/ FS-43

AT EACH END OF STEEL.

SECURE HP-10414 REINFORCING

WITH FS-43 ABOVE AND BELOW

STEEL.