Rice Lake Allen-Bradley Remote I/O User Manual
Page 11
Discrete Transfer Commands
7
14
0x0E
0000 1110
Clear Tare
16
0x10
0001 0000
Primary Units
17
0x11
0001 0001
Secondary Units
18
0x12
0001 0010
Tertiary Units
19
0x13
0001 0011
Units key press (toggle units)
20
0x14
0001 0100
Print Request
21
0x15
0001 0101
Display Accumulator
22
0x16
0001 0110
Clear Accumulator
23
0x17
0001 0111
Push Weight to Accumulator
32
0x20
0010 0000
Return Gross (integer)
33
0x21
0010 0001
Return Net (integer)
34
0x22
0010 0010
Return Tare (integer)
35
0x23
0010 0011
Return Piece Count
37
0x25
0010 0101
Return Current Display (integer)
38
0x26
0010 0110
Return Accumulator (integer)
39
0x27
0010 0111
Return Rate of Change (integer)
40
0x28
0010 1000
Return Peak (integer)
95
0x5F
0101 1111
Set Batching State
96
0x60
0110 0000
Batch Start
97
0x61
0110 0001
Batch Pause
98
0x62
0110 0010
Batch Reset
99
0x63
0110 0011
Batch Status
112
0x70
0110 0100
Lock Indicator Front Panel
113
0x71
0110 0101
Unlock Indicator Front Panel
114
0x72
0110 0110
Set Digital Input ON
115
0x73
0110 0111
Set Digital Input OFF
116
0x74
0110 1000
Read Digital Input Status
253
0xFD
1111 1101
No operation
254
0xFE
1111 1110
Reset Indicator
368
0x170
10111 0000
Set Register
402
0x192
11001 0010
Get Register
Decimal
Hex
Binary
Command
Table 3-2.
520 /720i/ 820i / 920i Remote Commands (Continued)