3 decimal point handling, Discrete transfer, Block transfer – Rice Lake Allen-Bradley Remote I/O User Manual
Page 9: Installation 5
Table 2-5. SW1 Switch Settings for Remote I/O Interface Rack Address
Rack Address
SW1 Switch Settings (LSB—>MSB)
Rack Address
SW1 Switch Settings (LSB—>MSB)
Decimal
Octal
3
4
5
6
7
8
Decimal
Octal
3
4
5
6
7
8
00
00
CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED
32
40
CLOSED CLOSED CLOSED CLOSED CLOSED
OPEN
01
01
OPEN
CLOSED CLOSED CLOSED CLOSED CLOSED
33
41
OPEN
CLOSED CLOSED CLOSED CLOSED
OPEN
02
02
CLOSED
OPEN
CLOSED CLOSED CLOSED CLOSED
34
42
CLOSED
OPEN
CLOSED CLOSED CLOSED
OPEN
03
03
OPEN
OPEN
CLOSED CLOSED CLOSED CLOSED
35
43
OPEN
OPEN
CLOSED CLOSED CLOSED
OPEN
04
04
CLOSED CLOSED
OPEN
CLOSED CLOSED CLOSED
36
44
CLOSED CLOSED
OPEN
CLOSED CLOSED
OPEN
05
05
OPEN
CLOSED
OPEN
CLOSED CLOSED CLOSED
37
45
OPEN
CLOSED
OPEN
CLOSED CLOSED
OPEN
06
06
CLOSED
OPEN
OPEN
CLOSED CLOSED CLOSED
38
46
CLOSED
OPEN
OPEN
CLOSED CLOSED
OPEN
07
07
OPEN
OPEN
OPEN
CLOSED CLOSED CLOSED
39
47
OPEN
OPEN
OPEN
CLOSED CLOSED
OPEN
08
10
CLOSED CLOSED CLOSED
OPEN
CLOSED CLOSED
40
50
CLOSED CLOSED CLOSED
OPEN
CLOSED
OPEN
09
11
OPEN
CLOSED CLOSED
OPEN
CLOSED CLOSED
41
51
OPEN
CLOSED CLOSED
OPEN
CLOSED
OPEN
10
12
CLOSED
OPEN
CLOSED
OPEN
CLOSED CLOSED
42
52
CLOSED
OPEN
CLOSED
OPEN
CLOSED
OPEN
11
13
OPEN
OPEN
CLOSED
OPEN
CLOSED CLOSED
43
53
OPEN
OPEN
CLOSED
OPEN
CLOSED
OPEN
12
14
CLOSED CLOSED
OPEN
OPEN
CLOSED CLOSED
44
54
CLOSED CLOSED
OPEN
OPEN
CLOSED
OPEN
13
15
OPEN
CLOSED
OPEN
OPEN
CLOSED CLOSED
45
55
OPEN
CLOSED
OPEN
OPEN
CLOSED
OPEN
14
16
CLOSED
OPEN
OPEN
OPEN
CLOSED CLOSED
46
56
CLOSED
OPEN
OPEN
OPEN
CLOSED
OPEN
15
17
OPEN
OPEN
OPEN
OPEN
CLOSED CLOSED
47
57
OPEN
OPEN
OPEN
OPEN
CLOSED
OPEN
16
20
CLOSED CLOSED CLOSED CLOSED
OPEN
CLOSED
48
60
CLOSED CLOSED CLOSED CLOSED
OPEN
OPEN
17
21
OPEN
CLOSED CLOSED CLOSED
OPEN
CLOSED
49
61
OPEN
CLOSED CLOSED CLOSED
OPEN
OPEN
18
22
CLOSED
OPEN
CLOSED CLOSED
OPEN
CLOSED
50
62
CLOSED
OPEN
CLOSED CLOSED
OPEN
OPEN
19
23
OPEN
OPEN
CLOSED CLOSED
OPEN
CLOSED
51
63
OPEN
OPEN
CLOSED CLOSED
OPEN
OPEN
20
24
CLOSED CLOSED
OPEN
CLOSED
OPEN
CLOSED
52
64
CLOSED CLOSED
OPEN
CLOSED
OPEN
OPEN
21
25
OPEN
CLOSED
OPEN
CLOSED
OPEN
CLOSED
53
65
OPEN
CLOSED
OPEN
CLOSED
OPEN
OPEN
22
26
CLOSED
OPEN
OPEN
CLOSED
OPEN
CLOSED
54
66
CLOSED
OPEN
OPEN
CLOSED
OPEN
OPEN
23
27
OPEN
OPEN
OPEN
CLOSED
OPEN
CLOSED
55
67
OPEN
OPEN
OPEN
CLOSED
OPEN
OPEN
24
30
CLOSED CLOSED CLOSED
OPEN
OPEN
CLOSED
56
70
CLOSED CLOSED CLOSED
OPEN
OPEN
OPEN
25
31
OPEN
CLOSED CLOSED
OPEN
OPEN
CLOSED
57
71
OPEN
CLOSED CLOSED
OPEN
OPEN
OPEN
26
32
CLOSED
OPEN
CLOSED
OPEN
OPEN
CLOSED
58
72
CLOSED
OPEN
CLOSED
OPEN
OPEN
OPEN
27
33
OPEN
OPEN
CLOSED
OPEN
OPEN
CLOSED
59
73
OPEN
OPEN
CLOSED
OPEN
OPEN
OPEN
28
34
CLOSED CLOSED
OPEN
OPEN
OPEN
CLOSED
60
74
CLOSED CLOSED
OPEN
OPEN
OPEN
OPEN
29
35
OPEN
CLOSED
OPEN
OPEN
OPEN
CLOSED
61
75
OPEN
CLOSED
OPEN
OPEN
OPEN
OPEN
30
36
CLOSED
OPEN
OPEN
OPEN
OPEN
CLOSED
62
76
CLOSED
OPEN
OPEN
OPEN
OPEN
OPEN
31
37
OPEN
OPEN
OPEN
OPEN
OPEN
CLOSED
63
77
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
Installation
5
2.3
Decimal Point Handling
Discrete Transfer
Discrete transfer commands return no decimal point information to the PLC. For example, a value of 750.1
displayed on the indicator is returned to the PLC as 7501.
Block Transfer
Block transfer commands support decimal point information with no special handling.