4 electrical interface to indicator, Bare, 1 (shield) – Rice Lake AutoLift HE Low-Profile Lift User Manual

Page 8: White, 2 (-signal), Green, 3 (+signal), Blue, 4 (-sense), Black

Advertising
background image

4

RoughDeck HE AutoLift

2.4

Electrical Interface to Indicator

Each scale kit includes 20 feet of 6-wire cable to connect the scale to the weight indicator. Push one end of this
cable into the junction box.
Connect the wires to the INDICATOR terminal (shaded area of Figure 2-1) as shown in Table 2-1. Pull out excess
and tighten the strain relief bushing to hold the cable snugly.

Figure 2-1. Junction Box Indicator Terminal.

Route the cable to the indicator in a manner that will protect the cable from damage. The best method is to route the
cable in conduit through the floor. Leave a strain relief loop to facilitate future lifting of the scale for servicing or
cleaning.

Figure 2-2. Cable Protection

Cable Color Code

Junction Box

Bare

#1 (Shield)

White

#2 (-Signal)

Green

#3 (+Signal)

Blue

#4 (-Sense)

Black

#5 (-Excitation)

Yellow

#6 (+Sense)

Red

#7 (+Excitation)

Table 2-1: Junction Box Connections.

CELL 1

CELL 4

CELL 2

CELL 3

INDICATOR

+EX

–EX

+SI

–SI

100 K

+SE

–SE

+EX

+EX

+EX

+EX

–EX

–EX

–EX

–EX

+SI

+SI

+SI

+SI

–SI

–SI

–SI

–SI

SHD

SHD

SHD

SHD

23126
Rev. A

SHD

JU1

JU2

JU3

JU4

100 K

100 K

100 K

LOAD CELL CABLE

STEEL COVER

FLOOR

SCREW

LOAD CELL CABLE

STEEL COVER

Advertising