4 reset to factory defaults – Rice Lake Chair Scales User Manual

Page 17

Advertising
background image

Chair Scale Technical and Operating Instructions - Scale Configuration

13

4.4

Reset To Factory Defaults

The configuration parameters may be reset to factory defaults while in the configuration mode. To do so, enter

the configuration mode. Press the

REWEIGH

key once to advance to displaying the software version (ID <->

11305). Press and hold the

BMI

key until

=DEF=

is displayed. At this point, if you wish to perform the default

function, press the

REWEIGH

key and the scale will show

DONE

, then it will restart. If you do not want to perform

the default function, press the

ON/OFF

key.

After performing the default function, the scale will require re-calibration. In addition, the scale will be set

up to a capacity of 600 lbs. The capacity varies by model - refer to the serial label on your scale and

reconfigure the capacity (FULL) and display divisions (rOUnd) as necessary in the configuration mode.

16

Set Option defaults

Set < - > 1

To change, press the Kg-Lb key.
0 - default
Options = (OPx)
1 = US default (US defaults are
OP1-1, OP2-0, OP3-0, OP4-0, OP5-0,
OP6-1, OP-7-0, OP8-1, OP9-1,
OP10-1).
2 = European 1 default
3 = European 2 default
9 = Used if OP1 through OP10 have
been changed to something other than
the factory default settings.

Note: Always set to 1 or 9 for US
indicators. To advance to the next
step, press the
REWEIGH key.

17

Determines the
automatic shut off
time when the scale is
not in use. Options are
between one and 20
minutes.
This is used when the
unit is battery
operated.

t-OFF <-> 5

Press and hold the Kg-Lb key to scroll
through the furthest right hand digit on
the display (0-9). If you want a value
from 10 to 19, with the display sitting
at 1, double press the Kg-Lb key and
10 appears. Press and hold the Kg-Lb
key to begin scrolling 10-19. If you
want a value of 20, with the display
sitting at 2, double press the Kg-Lb
key and 20 will appear.
To advance to the next step, press the
REWEIGH key.

18

StArt or SAvE

If no changes were made in the
parameters the display will
automatically show StArt and then
returns to normal weighing mode.
If a parameter was changed, the
display will show SAvE. To save
changes made, press the REWEIGH
key. To return to weigh mode without
saving changes, press the Kg-Lb key.

19

Con En

Replace the configuration jumper.

Step

Function

Display

Available Parameters

Table 4-1. Configuration Mode Menu