1 test mode – Rice Lake Chair Scales User Manual

Page 26

Advertising
background image

22

Chair Scale Technical and Operating Instructions

7.1

Test Mode

The test mode menu is a special mode used for checking four very important parameters which are useful in

knowing the system’s state and for troubleshooting. Entry into this mode is possible only when the scale is turned

off. Turn the scale on. While

Start

is displayed, press and hold the

REWEIGH

key until both the middle arrows

appear on the display.
The test mode has four parameters. They are:

Weighing

Internal count

Battery indication

Calibration factor

Alternating between the parameters is performed by pressing the

REWEIGH

key.

Press the

Kg-Lb

key to zero the scale in test mode.

Press the

Kg-Lb

+

REWEIGH

to exit weighing mode.

Figure 7-1. Test Mode Menu Structure

Table 7-2 lists the various display messages when testing the scale.

NOTE:

<-> means the display toggles between the two values.

Power On-Off

START

REWEIGH Key

TEST

Version

BAT

A-D

FACTOR

At

Press and
hold

Power Off

Remove Config/
Calibr. Jumper

Step

Function

Display

Available Parameters

1

Turn the scale on.
While StArt is
displayed, press and
hold the REWEIGH
key.

This enters into
the test mode of
the scale.

StArt

The scale automatically advances to Step
2.

2

Identifies the
software ID

IdEnt <-> 11007

Press the REWEIGH key to advance to
the next step.

3

Shows the current
weight value

tESt <-> 0.0

To zero the display, press the Kg-Lb key.
To advance to the next step, press the
REWEIGH key.

4

Shows the current
A/D count

A-d <-> XXXX

To advance to the next step, press the
REWEIGH key.

Table 7-2. Test Mode Menu