Rice lake indicators have no on/off switch. Before opening the unit, ensure the power cord is
disconnected from the power outlet.

The Ethernet card should NOT be used to communicate between buildings. The Ethernet port is not
suitable for connection to circuits used outside the building and is subject to lightning or power
faults.

Use a wrist strap to ground yourself and protect components from electrostatic discharge (ESD)
when working inside the indicator enclosure.

This unit uses double pole/neutral fusing which could create an electric shock hazard. Procedures
requiring work inside the indicators must be performed by qualified service personnel only.

The indicator enclosure must be opened to install the Ethernet card.

Figure 2-1. Ethernet Interface Card

2.1

Ethernet Card Installation

1. Disconnect the indicator from power source.

2. Place indicator on an antistatic work mat. Remove screws that hold the cover to the enclosure body, then

lift the cover away from the enclosure and set it aside.

3. Remove plug from cord grip on the indicator that will be used to run the Ethernet cabling.

4. Carefully align the option card connector with the connector on the indicator’s CPU board. Press down

to seat the option card in the CPU connector.

Refer to the indicator manual for exact pin locations.

5. Use the screws provided in the option kit to secure the other end of the option card to the threaded

standoffs on the indicator’s CPU board.

6. Ensure jumper JP1 on the Ethernet card is in the +6V position for installation.

Warning

Caution

C8

JP1

TP5

TP9

C7

GND

C6

VR1

J2

U2

TP3

TP1

TP4

TP2

J3

1

J4

1

LX1

J1

1

8

33

1

+6V

INPUT

+5V

Aux +5V

TxD +

TxD -

RxD -

EGnd

RxD+

EGnd

RESET

MANUAL

SW 1

TP6

TP7

TP8

C2

C1

C3

C5

C4

U1

2004

83267-A

P/N Revision

Assembl y

D L

D

1

Gnd

232-Rx

Gnd

232-Tx

8

1-TX+
2-Tx-
3-Rx+
6-Rx-
7-SHLD

RJ-45 Connector

1

8

Note

Advertising