Symbologies

150

QuickScan® QD2100

GS1 DataBar Expanded — cont.

GS1 DataBar Expanded Set Length 2

This feature specifies one of the barcode lengths for

GS1 DataBar Expanded Length

Control

. Length 2 is the maximum label length if in

Variable Length

Mode, or the sec-

ond fixed length if in

Fixed Length

Mode. Length includes the barcode’s data characters

only.

The length can be set from 1 to 74 characters. A setting of 0 specifies to ignore this length
(only one fixed length).

Follow these instructions to set this feature:

1. Determine the desired character length (from 1 to 74). Pad the number with leading

zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.

2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming

Mode.

3. Scan the barcode: SELECT GS1 DataBar EXPANDED LENGTH 2 SETTING.

4. Scan the appropriate two digits from the keypad in

Appendix E, Keypad

, that represent

the length setting which was determined in the steps above. You will hear a two-beep indi-
cation after the last character.

5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming

Mode.

This completes the procedure. See

Table 20

for some examples of how to set this feature.

Table 20. GS1 DataBar Expanded Length 2 Setting Examples

NOTE

If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.

STEP

ACTION

EXAMPLES

1

Desired Setting

00 (ignore second

length)

07 Characters

52 Characters

74 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT GS1 DataBar EXPANDED LENGTH 2 SETTING

4

Scan Two Characters From

Appendix E, Keypad

‘0’ and ‘0’

‘0’ and ‘7’

‘5’ and ‘2’

‘7’ and ‘4’

5

Scan ENTER/EXIT PROGRAMMING MODE

Advertising