Scanning features, Scan mode – Rice Lake Datalogic QuickScan QD2100 Linear Imager Hand-held Scanner User Manual

Page 37

Advertising
background image

Scanning Features

Product Reference Guide

29

Scanning Features

Scan Mode

Selects the scan operating mode for the reader. Selections are:

Trigger Single —

When the trigger is pulled, scanning is activated until one of the fol-

lowing occurs:

-

Scanning Active Time

has elapsed

- a label has been read
- the trigger is released

This mode is associated with typical handheld reader operation: when the trigger is
pulled, scanning starts and the product scans until the trigger is released, or a label is read,
or the maximum

Scanning Active Time

has elapsed.

Trigger Hold Multiple —

When the trigger is pulled, scanning starts and the product

scans until the trigger is released or

Scanning Active Time

has elapsed. Reading a label does

not disable scanning.

Double Read Timeout

prevents undesired multiple reads of the same

label while in this mode.

Trigger Pulse Multiple —

When the trigger is pulled, continuous scanning is activated

until

Scanning Active Time

has elapsed or the trigger has been released and pulled again.

Double Read Timeout

1

prevents undesired multiple reads of the same label while in this

mode.

Flashing —

The reader flashes

1

on and off regardless of the trigger status. Flash rate is

controlled by

Flash On Time

and

Flash Off Time

. When Flash is ON the imager reads con-

tinuously. When Flash is OFF scanning is deactivated.

Always On —

No trigger pull is required to read a barcode. Scanning is continually on.

If the trigger is pulled, the reader acts as if it is in

Trigger Single

Mode.

Double Read

Timeout

1

prevents undesired multiple reads of the same label while in this mode.

Stand Mode —

No trigger pull is required to read a barcode. Scanning is turned on au-

tomatically when an item is placed in reader’s field of view. If the trigger is pulled, the
reader acts as if it in single read mode.

Double Read Timeout

1

prevents undesired multiple

reads of the same label while in this mode.

Trigger Object Sense —

This mode is similar to Stand Mode, except that a trigger pull

is required to activate the decoder.

1. Controlled by

Flash On Time

.

Advertising