Serial output – Rice Lake Intercomp CS 5000 - Users Manual User Manual

Page 28

Advertising
background image

CS5000, Users

Rev V, January, 2008

28

Serial Output


The CS5000 base has available two communications channels, the standard interface for
both is RS-232. One is equipped with a CTS (clear to send) line and designed primarily for
hookup to a printer. The second channel consists of signal wires only and is designed
primarily for hookup to a score board or computer.

Channel 1 outputs a ticket:


Channel 2 outputs the net weight:


There is a five switch dip pak located on the main circuit board inside the base unit, it's
switches have the following meanings:

Switch #

On

Off

Function

1

1200

9600

Channel 1 baud rate

2

1200

9600

Channel 2 baud rate

3

on

off

Channel 1 continuous print

4

on

off

Channel 2 continuous print

5

on

off

RF interface (must be turned on, on CS5000)

The Items in bold indicate the suggested defaults.

NOTE: The RS-232 communication parameters: Fixed 8 data bits, no parity, 1 stop bit.

Each channel will print under two conditions:

1: If the print key is pressed.

2: If the continuous print is turned on.

cr/lf
-XXXXXX.X lb G cr/lf
-XXXXXX.X lb N cr/lf
-XXXXXX.X lb T cr/lf
-XXXXXX.X lb TOTAL cr/lf
lf
lf
JAN DD, 19YY HH:MM:SSam cr/lf (the 19 could be 20, and the a could be p)
lf
lf

-XXXXXX.X lb cr/lf

Advertising