Scale Calibration

Before you can calibrate the scale, verify and set all scale parameters which are noted in “Scale Configuration”

on page 7.
Remove the configuration/calibration jumper (see page 7). Turn the scale on. While

StArt

is displayed, press and

hold both the

Kg-Lb

key and the

REWEIGH

keys until

CAL

is displayed.

NOTE: The calibration weight must be no less than 60 lb (28 kg) and no more than 300 lb (135 kg).

The following table illustrates the calibration procedure.

Table 5-1. Calibration Menu

Step

Function

Display

Available Parameters

1

Turn the scale on.
While START is
displayed, press and
hold the Kg-Lb and
REWEIGH keys until
CAL is displayed.

Enters into calibration
mode

StArt

The scale automatically advances to
Step 2.

2

Cal mode entered

CAL

To advance to the next step, press the
REWEIGH key.

3

Gravity value at the
point of calibration

GrAv<-> 9.8062

Use the numeric data entry (See Section
4.0 for more information on Gravity
Correction) to change the value. To
advance to the next step, press the
REWEIGH key.

4

Sets the value of the
calibration weight
you are going to use
for calibrating the
span value of the
scale.

LOAd <-> XXX.X

Use the numeric data entry (explained in
“Numeric Data Entry” on page 8) to set a
calibration weight.
To advance to the next step, press the
REWEIGH key.

5

CLEAr

Clear the platform and be sure of the
scale’s stability.
To advance to the next step, press the
REWEIGH key.

6

Calibrate Zero

- - - - -
PUT<->XXXX

Place the requested weight on the scale.
This will display for a few seconds.
To advance to the next step, press the
REWEIGH key.

7

Calibrate Span

CAL
FAC tOr <-> X.XXX

This will be displayed for a few seconds
and shows the current calibration factor.
To advance to the next step, press the
REWEIGH key.

8

SAvE

To save the new calibration, press the
REWEIGH key.
To exit without saving the calibration
press the ZERO key.

9

dONE

The scale displays that it has saved that
calibration value and automatically
advances to the last step.

10

StArt

The scale reboots.

11

Con En

Replace the configuration jumper.

Advertising