3 mounting, 1 pr 6002/02s, ../03s, Installation manual mounting kits pr 6002 – Rice Lake PR6202 Hygienic Weigh Module Kits User Manual

Page 21

Advertising
background image

Installation Manual

Mounting Kits PR 6002

Sartorius

EN-19

4.3

Mounting

4.3.1 PR 6002/02S, ../03S

Note:

The following steps must be performed at all supporting points of the weighing
object (e.g. vessel)!


• Put the mounting kit on the foundation (7) and tighten the bolts (5) lightly.
• Place the weighing object (1) on the mounting kit and adjust the mounting kit position over the

bore holes.

• Adjust the position of the washers over the bore holes so that the bore holes are covered.
• Tighten the bolts (3) of the upper mounting plate (2) and the bolts (5) of the lower mounting

plate (6) with the recommended tightening moment, see Chapter 4.2.

• Lift the weighing object (1) approx. 5 mm, a required lifting tool.
• Clean the load cell base in both load disks.
• Protect the contact surfaces between load cell/load disks with sufficient grease

.

• Position and install the load cell (4) using the rubber ring for mounting, see Chapter 2.4.
• Put the weighing object (1) again on the mounting kit, using a required lifting tool.
• Remove the rubber ring, see Chapter 2.4.

Advertising