3 internal lift-off protection, 4 rubber ring for mounting, Mounting kits pr 6002 installation manual – Rice Lake PR6202 Hygienic Weigh Module Kits User Manual

Page 6

Advertising
background image

Mounting Kits PR 6002

Installation Manual

EN-4

Sartorius

2.3

Internal Lift-off Protection

All mounting kits are equipped with an internal lift-off protection; i.e. no bore holes other than the

mounting holes for the kit are required.
The Lift-off protection is realized by a bolt (2), nut (1) and a retainer (3). Bolt and nut are delivered in a

bag.

2

1

3

• Mount the lift-off protection after installation/alignment of the load cell.
• Do not turn the slots by more than 30° from the vertical.

2.4

Rubber Ring for Mounting

1…10 t

25…50 t

The rubber ring for mounting is used for vertical installation of the load cell.
• Place the rubber ring on the lower load disk.
• Position the load cell between the load disks.
• Lower the vessel and tighten the mounting screws.
• Pull out the four tabs on the rubber ring by approx. 15 mm so that the rubber ring is removed from

between load disk and load cell.

• Then tear or cut off the rubber ring to remove it completely.

Advertising