Installation

Steam Connection

Never touch internal or external steam pipes, connections, or
components. These surfaces can be extremely hot and will cause severe
burns. The steam must be turned off and the pipe, connections, and
components allowed to cool before the pipe can be touched

For machines equipped with optional steam
heat, install piping in accordance with
approved commercial steam practices.

Steam requirements are shown in the table
below. Failure to install the supplied steam
filter may void the warranty.

MODEL
STEAM INLET and CONSUMPTION:
Steam inlet size

DN

in

20

3/4

Required steam to heat bath 10F (5.55C)LOW

kg

lbs

3.15

7

Required steam to heat bath 10F (5.55C)HIGH

kg

lbs

4.77

10.5

Average Steam consumption per cycle

kg

lbs

72

158

MODEL
STEAM INLET and CONSUMPTION:
Steam inlet size

DN

in

20

3/4

Required steam to heat bath 10F (5.55C)LOW

kg

lbs

3.8

8.4

Required steam to heat bath 10F (5.55C)HIGH

kg

lbs

5.8

12.76

Average Steam consumption per cycle

kg

lbs

88

194