Routine Maintenance

36

Maintenance

5. Remove back panel and check overflow
hose and drain hose for leaks.

6. Unlock the hinged lid and check the
supply dispenser hoses and hose
connections.

7. Clean inlet hose filter screen:

a.
Turn water off and allow valve to

cool, if necessary.


b.
Unscrew inlet hose and remove

filter screen.


c.
Clean with compressed air and

reinstall. Replace if worn or damage.

8. Tighten motor mounting bolt lock nuts
and bearing bolt lock nuts, if
necessary.
9. Use compressed air to clean lint from
motor.
10. Clean external water and steam filters.

Quarterly

NOTE: Disconnect power to the machine
before performing the quarterly
maintenance procedures.

1. Tighten door hinges and fasteners, if
necessary.

2. Tighten anchor bolts, if necessary.

3. Check all painted surfaces for bare metal
(matching paint is available from the
manufacturer.)

a. If bare metal is showing, paint with

primer or solvent-based paint.


b. If rust appears, remove it with sand

paper or chemical means. Then
paint with primer or solvent-based
paint.

4. Clean steam filter, where applicable. See
picture of steam filter.

NUT

ELEMENT

1. Turn off steam supply and allow time
for the valve to cool if necessary.

2. Unscrew nut.

3. Remove element and clean.

4. Replace element and nut.