Electrical, Features – Ryobi RYI2011T User Manual

Page 13

Advertising
background image

9 — English

ELECTRICAL

Application/Equipment

Estimated

Run Watts*

Estimated

Starting

Watts*

Emergency / Home Standby
Lights (qty. 4 x 75 W)

300

300

Refrigerator

700

1350

46 in. Flat Panel Television

190

190

Satelite Receiver

250

250

Portable Fan

40

120

Heater

1300

1300

Laptop

250

250

Slow Cooker

270

270

Radio

50

50

Job Site
Electric Drill − 3/8 in.

600

1000

Quartz Halogen Work Light

1000

1000

Reciprocating Saw

960

1920

Circular Saw − 7-1/4 in.

1400

2300

Miter Saw − 10 in.

1800

1800

Air Compressor − 1/4 HP

970

1600

Airless Sprayer − 1/3 HP

600

1200

*Wattages listed are approximate. Check tool or appliance for actual wattage.

POWER MANAGEMENT

To prolong the life of the generator and attached devices,

it is important to take care when adding electrical loads to

the generator. There should be nothing connected to the

generator outlets before starting its engine. The correct and

safe way to manage generator power is to sequentially add

loads as follows:
1. With nothing connected to the generator, start the engine

as described later in this manual.

2. Plug in and turn on the first load, preferably the largest

load you have.

3. Permit the generator output to stabilize (engine runs

smoothly and attached device operates properly).

4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Never add more loads than the generator capacity. Take

special care to consider surge loads in generator capacity

as previously described.

CAUTION:

Do not overload the generator’s capacity. Exceeding the
generator’s wattage/amperage capacity can damage the
generator and/or electrical devices connected to it.

FEATURES

PRODUCT SPECIFICATIONS

ENGINE
Engine Type ......................... Single Overhead Cam (SOHC)
Bore x Stroke ............................................. 88 mm x 64 mm
Cooling System ...................................................Forced Air
Compression Ratio ...................................................... 8.5:1
Starting System ......................................................... Recoil
Ignition System ............................................................ T.C.I.
Spark Plug ................................................NHSP LD A7RTC
Engine Lubricant Volume......................................... 0.42 qt.
Fuel Volume ..............................................................1.0 gal.

GENERATOR
Rated Voltage .........................................120 V AC/12 V DC
Rated Amps ..........................................13.33A AC/7.5A DC
Rated Running Watts ............................................. 1,600 W
Starting Watts ......................................................... 2,000 W
Rated Frequency ........................................................ 60 Hz