background image

EdgeAccess Universal Chassis System

Model 1502 Domain Management Module

3-2

4. When the main Windows screen (desktop) appears, click Start, highlight Programs,

Accessories, the HyperTerminal Folder, and click HyperTerminal.

5. At the Connection Description dialog, select an icon, enter a name for the connection to the

system, and click OK.

6. At the Connect To dialog, pull down the Connect using menu, select the COM port, and click

OK.

7. At the COM port Properties dialog, set these values to communicate with the DMM:

• Bits per second: 19200
• Data bits: 8
• Parity: None
• Stop bits: 1
• Flow control: None

8. Click OK. At the prompt to save the HyperTerminal file, select Yes.

Management User Interface

The Management User Interface for the DMM provides screens for setup, monitoring, and
diagnostics. You can access the screens directly by connecting to the serial port of the DMM in
the chassis or by establishing a Telnet session with the DMM. These sections discuss the screens
for the DMM. For details about any other module in the domain, see the user manual for that
module.