6l134, l135, l136, l137: t1 and e1, L134, l135, l136, l137: t1 and e1 -7 – CANOGA PERKINS 2370 High-Speed Universal Fiber Optic Modem User Manual

Page 21

Advertising
background image

EdgeAccess Universal Chassis System

Model 2370 Model User Manual

3-7

3.6

L134, L135, L136, L137: T1 and E1

The L134, L135, L136, and L137 ELIMs are electrically compatible with T1 or E1 specifications.
Tables 6 and 7 show the connector pinouts.

L134 supports T1 and transmits AMI or B8ZS code. The ELIM includes an RJ-45 connector; use

a 100 ohm twisted pair cable to connect to the local network equipment.

L135 supports T1 and transmits AMI or B8ZS code. The ELIM includes a DA-15 connector; use

a 100 ohm twisted pair cable to connect to the local network equipment.

L136 supports E1 and transmits AMI or HDB3 code. The ELIM includes an RJ-45 connector;

use a 120 ohm twisted pair cable to connect to the local network equipment.

L137 supports E1 and transmits AMI or HDB3 code. The ELIM includes a DA-15 connector;

use a 120 ohm twisted pair cable to connect to the local network equipment.

These ELIMs include two LEDs, LOS and AIS. See Table 8.

Table 6. RJ-48 Pinout

Pin

Direction

1, 2

Tx (Output)

4, 5

Rx (Input)

Table 7. DA-15 Pinout

Pin

Direction

1, 9

Rx (Input)

3, 11

Tx (Output)

Table 8. T1 and E1 ELIM Status LEDs

LED

Color

Description

LOS

Off

Normal

Red

Loss of received signal

AIS

Off

Normal

Amber

Alarm; receiving all 1s

Advertising