4.16 Utilities

Use the Utilities screen to set values for general parameters and to run the diagnostic PING. See
Figure 21 and Table 20. To access the Utilities screen, follow this step:

1. From the Main Menu, type

6

, Utilities, and press <Enter>. The Utilities menu appears.

------------------------------UTILITIES----------------------------------

1) Set Date and Time
2) Change Password
3) VT100 Baud Rate

19200

4) Modem/Slip/PPP Baud Rate

19200

5) Modem Initialization String

AT

6) Reset Configuration To Default
7) Copy Configuration
8) PING Generation

Figure 21. Utilities Menu Screen

Table 20. Utilities Menu Options

Item

Definition

1) Set Date and Time

Change the time and date information for the modem if needed; if in
a chassis with a DMM, the DMM date and time overrides the 2370

2) Change Password

Add, delete, or update the password for the user interface

3) VT100 Baud Rate

Select the baud rate, 9600 or 19200 bps, for a VT100 terminal
connection

4) Modem/Slip/PPP Baud
Rate

Select the baud rate, 9600, 19200, 38400, 57600, or 115200 bps for
the modem/SLIP/PPP serial port

5) Modem Initialization
String

The default string is "

at

"

6) Reset Configuration
To Default

Restores all configurable settings to the defaults except for: date
and time; password; BOOTP; Telnet timeout

7) Copy Configuration

Copy the alarm override configuration to the remote modem