15system alarms, System alarms -16, Figure 20. system alarms screen -16 – CANOGA PERKINS 2370 High-Speed Universal Fiber Optic Modem User Manual

Page 40: Table 19. system alarms definitions -16, 15 system alarms

Advertising
background image

EdgeAccess Universal Chassis System

Model 2370 Model User Manual

4-16

4.15 System Alarms

The System Alarms screen reports alarms and faults on the local 2370 and the remote 2370. See
Figure 20 and Table 19. To view current alarm status, follow these steps:

1. From the Main Menu, type

5

, Alarms, and press <Enter>. The System Alarms report appears.

2. To return to the Main Menu, press <Esc>.

------------------------------SYSTEM ALARMS-------------------------------

Local

Remote

Modem Redundancy Status

N/A

N/A

Configuration Errors

No

No

Fiber Loss of Signal

No

No

Electrical Loss of Signal

No

No

SQL Rx

OK

OK

Chassis Management

N/A

N/A

Alarm Relay Inputs

N/A

N/A

Power Supply Primary

OK

OK

Power Supply Secondary

N/A

N/A

Fan

N/A

N/A

Power-On Self Test

OK

OK

Figure 20. System Alarms Screen

Table 19. System Alarms Definitions

Item

Definition

Modem Redundancy
Status

Reports if redundancy is Active, Inactive, or turned off (N/A)

Configuration Errors

Check that the local and remote modems have compatible set ups,
including software version

Fiber Loss of Signal

Checks if optical loss of signal errors

Electrical Loss of Signal When LOS detection is On, checks if electrical loss of signal occurs
SQL Rx

Checks if squelch occurs

Chassis Management

Reports OK if 2370 is in UCS 1000 with DMM or N/A if 2370 is in
1040, 1050, or UCS 1001

Alarm Relay Inputs

Reports Loss if CLS occurs or OK if signal is good; UCS 1001, only

Power Supply Primary

Reports function of main power supply

Power Supply Secondary Reports function of second power supply
Fan

Reports fan failure

Power-On Self Test

Reports OK or faulty hardware or software

Advertising