4.17 PING

Use the PING Generation screen to test the connection to a specific IP address. To use the PING
option, see Figure 20 and follow these steps:

----------PING Generation----------------------------------

IP Address to PING: 0.0.0.0
PING count (1 to 255, 0 = forever):

0

Use TAB key to move to other field,
and ENTER to validate.

Figure 22. PING Generation Screen

1. From the Main Menu, type

6

, Utilities, and press <Enter>.

2. From the Utilities menu, type

8

, PING Generation, and press <Enter>.

3. At the prompt, type the IP address to PING and press <Tab>.

4. At the prompt, type the number of times to send a PING, from 1 to 256, or type

0

to PING

continuously every 3 seconds, and press <Enter>.
"

PING response received...

" indicates a good connection;

"

TIMEOUT: Unable to reach [IP address]...

" indicates a faulty connection.

5. To stop the PING and return to the Utilities menu, press <Esc>.

4.18 Software Upgrade

Use the Software Upgrade screen to check the current version of the firmware and upgrade it and the
remote 2370, if necessary. See Figure 23. To access the Software Upgrade screen and check the
software version, follow these steps:

1. From the Main Menu, type

7

, Software Upgrade, and press <Enter>. The Software Upgrade

screen appears.

---------------------------SOFTWARE UPGRADE-------------------------------

Local

Remote

Pri Offline

Sec.

Pri Offline

Sec.

Last Data

Last Data

Last Data

Active Firmware

01.00

01.00

Inactive Firmware

01.01

01.01

Bootcode

05.00

05.00

1)

Software Reset

Reset

Reset

Reset

Reset

2)

Swap Bank

Swap

Swap

Swap

Swap

3)

Copy Software from Source modem to Destination modem

4)

Get New File with TFTP

Figure 23. Software Upgrade Screen