CANOGA PERKINS 9145E NID Software Version 3.1 User Manual

Page 148

Advertising
background image

Service OAM

9145E NID Software User’s Manual

SOAM Configuration

133

Conflicting VIDs

: This error condition occurs when two or more MAs or MEGs in the sys-

tem, at the same level, have overlapping VIDs associated with them, and for each MA, an
UP MEP is configured in the system. That is, it is an error to have two UP MEPs monitor-
ing the same VLAN, at the same level.

CFMLeak

: This error condition occurs when two or more MAs or MEGs, having overlap-

ping VIDs, are configured such that for the lower level MA, there is no UP MEP associ-
ated with a given port, and there are no down MEPs in the entire system; while for the
higher level MA, there is a MEP associated with a port (the port where the error is
detected). That is, there is no boundary for the lower level MA in the system, while there
is a boundary for the upper level MA

To view the SOAM Configuration Errors screen:

1. On the SOAM System Level Configuration screen (Figure 11-8), type 11 and press Enter. The

Configuration Errors screen (Figure 11-9) opens.

2. The Configuration Error screen lists the VLAN, port, and error. Figure 11-9 shows a typical error on

the user port and two typical errors on the network port.

3. Press Esc to return to the SOAM System Level Configuration screen. Press Esc again to return to

the SOAM Configuration screen.

Figure 11-9 SOAM Configuration Errors screen

Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2009
9145E-101-1-0 V03.10(GA0014) 05:15:27
--------------------------SOAM CONFIGURATION ERRORS----------------------------

VLAN PORT Errors
300 User Conflicting VIDs
300 Network CFM Leak, Conflicting VIDS

Select [(F)irst, (P)rev, (N)ext, (L)ast] to change pages,
ESC to return:

------------------------------------Messages-----------------------------------

Advertising