EMS-D10 Pilot’s User Guide

4-3

EMS Times/Auxiliary Page

Available in 1/2 | 1/2 format

This page displays times information on the left half of the screen and user-customizable auxiliary information on the
right half of the screen.

The times half is divided into three sections: TIME, TIMERS, and ENGINE
TIMERS.

 The TIME section shows the present time (both local and Zulu) and can be

displayed in either standard or military time formats.

 The Flight Timer shows the total amount of time that oil pressure is above 15

PSI since the EMS-D10 was turned on; it will not reset until the next time the
EMS-D10 is power-cycled and oil pressure reaches 15 PSI. The Trip Timer
shows cumulative flight time since a manual reset. The third line of this
section contains the general purpose Timer which can be used for a variety of
functions including a tank timer.

 The Tach Timer keeps track of engine time (normalized to the user-configured cruise RPM). The Hobbs Timer

records the duration of time engine oil pressure is at 15 PSI or higher.

When ENGINE TYPE is set to ROTAX (in EMS > SETUP > GLOBAL), only Hobbs time is displayed in the ENGINE
TIMERS section; Tach time is not displayed, due to specific manufacturer recommendation.

The auxiliary half is customizable and allows you to display up to four different info items. You may choose from any of
the available info items. For more information on configuring this display (as well as info items on the EMS Main Page),
see the Global Configuration Settings section on page 7-5.