Appendix

8-2

EMS-D10 Pilot’s User Guide

EMS SERIAL DATA OUTPUT

The format for the data sent out the EMS RS232 port follows. General purpose and contact inputs which are sourced
from the HS34 are not output via the serial stream.

Parameter

ASCII

Characters

Units

Example

Zulu Hour

2

Hours

12 (12 hrs)

Zulu Min

2

Minutes

12 (12 mins)

Zulu Sec

2

Seconds

12 (12 secs)

Fraction

2

1/64 of sec

12 (12/64 sec)

Manifold Pressure

4

inHg x 100

1215 (12.15inHg) (using 5/100 increments)

Oil Temp

3

º F

123 (123

o

F) or -12 (-12

o

F)

Oil Pressure

3

PSI

099 (99PSI)

Fuel pressure

3

PSI x 10

123 (12.3psi)

Volts

3

volts x 10

123 (12.3V)

Amps

3

amps

012 (12A) or –12 (-12A)

RPM

3

RPM/10

123 (1230 RPM)

Fuel Flow

3

GPH x 10

123 (12.3gph)

Gallons remaining

4

Gallons x 10

1234 (123.4g) or –123 (-12.3g)

Fuel_Level_1

3

Gallons x 10

123 (12.3g)

Fuel_Level_2

3

Gallons x 10

123 (12.3g)

GP_1

8

See table below

3 char label; 5 char data; see GP output table

GP_2

8

See table below

3 char label; 5 char data; see GP output table

GP_3

8

See table below

3 char label; 5 char data; see GP output table