Alerts

5-2

EMS-D10 Pilot’s User Guide

“THIS.” Alert messages sourced from another Dynon product are preceded by the label “DSAB.” Pressing
SILNCE or ACK on any unit in the system silences or confirms the alarm on all units in the system. See the
EMS-D10 Installation Guide for more information.

If installed, either the HS34 or AP74 (but not both) can be configured to output EMS, EFIS, and AOA alarm
information with tones (such as with direct audio connections to the EMS and EFIS), or via spoken voice alerts.
When configured for voice alerts, the HS34 reads out an alarm that occurs, such as “CHT 1 HIGH” or “LOW
FUEL.” These voice alarms can be acknowledged and silenced just like the EMS tone.

SHOW PAGE

If the alarming measurement is not displayed on your current screen, or is available on a page which displays it better, a
SHOW [PAGE] button is included in the alarm menu. [PAGE] is replaced with the name of the actual page that is
displayed when you press the button. Press this button to display the page where the alarming measurement is best
displayed. From there, you may press GO BACK to return to your original screen, leaving the alarm indications active,
or press ACK to remove the alarm indications and return to your original screen.

ALARM SILENCING

To silence the audio alarm, press the SILNCE button.

ALARM ACKNOWLEDGEMENT

To acknowledge the alarm, press the ACK button. The ACK button has a number next to it indicating the number of
currently posted alarms. If this number is higher than 1, after you press ACK the alarm text for the next posted alarm is
displayed in the alarm bar. Pressing ACK does the following:

 Silences the audio alarm