Appendix – Dynon Avionics EMS-D10 Pilots Users Guide User Manual

Page 41

Advertising
background image

EMS-D10 Pilot’s User Guide

8-1

8. APPENDIX

This appendix contains information not covered in the main section of the manual. This section contains reference tools
such as a detailed description of the serial data format output by the EMS-D10, a specifications sheet, and a
troubleshooting guide. This section also contains details regarding EMS-D10 servicing.

Appendix A: Serial Data Output

The EMS-D10 outputs text data through its serial port constantly during normal operation. Technical information on the
installation and connection to this serial port can be found in the EMS-D10 Installation Guide. To log EMS data you
must connect the serial port to a PC. This serial data can be logged using any standard serial terminal program such as
HyperTerminal®. It can then be parsed into its respective columns by many spreadsheet programs including Microsoft
Excel®. All numbers are output in decimal and are standard ASCII. To view the data using a terminal program, the
following settings should be used for the serial port:
Baud rate:

115200

Data:

8

bit

Parity:

none

Stop:

1

bit

Flow control:

none

Advertising