Checking and adjusting – Leica Geosystems TPS1100 Professional Series - User Manual User Manual

Page 35

Advertising
background image

35

TPS1100 - User Manual 2.2.1en

Checking and adjusting

6

10

12

21

If the differences between the hori-
zontal and vertical angles do not
exceed ±27' ( ±0.5 gon ), the display
shows that the instrument is ready to
measure. The user is made aware by
an acoustic signal that the

key is

redefined as 'OK'.

V-index error , continued

Confirms the readiness to
measure and changes the
display.

Sight the target accurately again.

Starts the second
measurement.

After the measurements are complete,
the older and newly-determined V-
index errors are displayed.

Stores the new values.

Repeats the complete V-
index error determination

procedure.

Leaves the old values
unchanged.

If the value of the V-index
error (i) exceeds 54' (1 gon)

you should repeat the measurement
procedure. If this value is exceeded
repeatedly, please contact service.

Main\

V-Index Error

old new

i Vind: 0°00'03" -0°00'22"

Accept new value(s)?

YES RETRY

NO

MC

QUIT

Telescope Positioning

Hz- and V-positioning:

Set direction(s) to zero.

Hz

:

0°00'00"

V

:

0°00'00"

OK

ABORT

MC

QUIT

Main\

V-Index Error

Aim accurately at the same

target in other face

Hz

:

163°18'54"

V

:

266°12'19"

MEAS

MC

QUIT

Advertising