82

System functions

TPS1100 - User Manual 2.2.1en

The Check Orientation dialog allows
to check the orientation to a known
backsight point, and to reset the
orientation if necessary.

Activating the function "Check
Orientation".

Check Orientation

.....\ Check Orientation

Station Id

:

1

Backs. Id

:

BS

Refl. Ht.

:

1.650 m

Azimut

:

100.2222 g

Hz

:

95.6650 g

∆∆∆∆∆

Hz

:

-0.0059 g

CONT DIST POSIT SET

VIEW

LAST

MC

HELP

QUIT

Horiz Dist

:

-----

∆∆∆∆∆

HorizDist

:

-----

Elevation

:

-----

∆∆∆∆∆

Height

:

-----

Enter the Backsight Id. With

the

appropriate point will immediately be
searched for in the data file and, if
the search is successful , the
coordinates will be assigned to the
backsight point.
Additionally the calculated azimuth to
the point will be shown.

After the reflector height has been
entered, target the backsight point
and measure the distance and/or the
direction and compare azimuth with
HZ.

Leave the dialog and continue
work.

Measure distance. Distance
and difference between

calculated and measured distance to
the backsight point will be shown.

Position the telescope to the
backsight point. For motorised

instruments only!

The instrument positions
automatically back to the start
position when leaving the "Check
Orientation" function. This is
particularly suitable for RCS-
applications.

Target the backsight point
accurately and reset the

orientation.

Search and display the
coordinates of the point found

in the active data job.

If Orientation was set more
than once, LAST recalls the

last backsight point and azimuth.