MIDI Bank and Channel Programming

When this function is called, the LCD will appear as
follows:

MIDI CONTROL

BANK:x^ ch= xx

Use the PARAMETER INCREMENT/DECREMENT
keys to select the desired BANK, and the MEMORY
INCREMENT/DECREMENT keys to select the desired
MIDI channel number for that BANK. When "CH =
OMNI" is selected, reception will be carried out on

all 16 MIDI channels simultaneously. When CH =
OFF is selected, MIDI reception will be turned OFF.

a

A

PA RAM

ETER

Use the PARAMETER INCREMENT/DECREMENT

keys to set the MIDI program number (PGM), and the
MEMORY INCREMENT/DECREMENT keys to select

the SPX90II memory number (MEM) to be called
when that program number is received. For example,

if "PGM 12 = MEM4" isset, SPX90II memory number

4 will automatically be called whenever voice number

12 is selected on your MIDI synthesizer. The MIDI
program number range is from 1 to 128, while the
SPX90II memory number range is from 1 to 90.

/

FOOTSWITCH MEMORY RECALL RAN^

The SPX90II permits memory number selection via a
footswitch

plugged

into

the

front-panel

MEMORY/TRIGGER jack. The fourth function ac­

cessed by the UTILITY key-FOOTSWITCH MEMORY

RECALL— permits setting the range of memory num­

bers to be selected via the footswitch.

MIDI CONTROL

BANK : A

c h = X X

y

Selected bank

1

'

MIDI CONTROL

BANK : A

c h = 1

F.SW MEMORY RCL

'

RANGE 1 TO 30

V

If, for example, the RANGE is set to "1 TO 30" as

shown on the LCD above, each press on the footswitch
will successively call the next highest memory number:

1

2 ^ 3 .... 30 -> 1. Note that the sequence returns

to the first number in the range once the highest number

is passed. Reverse sequences can be programmed by

entering the highest number in the range before the
lowest.

Selected channel

Setting MIDI Program Number/SPX90 Memory
Number Combinations.

When this function is called by pressing the utility key
again, the LCD will appear as follows:

F.SW MEMORY RCL

RANGE 34 TO 31

In this case the sequence is: 34 -> 33 ^ 32 -»• 31

34, etc.

MIDI PGM CHANGE

PGMxxx = MEM

X X

a

Al

ETER

V

MIDI PGM CHANGE

PGM 12 = MEM

X X

A,

VI

MIDI PGM CHANGE

PGM 12 = MEM 4