Chang Yue Industrial KN-8828P User Manual

Page 15

Advertising
background image

15

TARGET TIME and REMAINING TIME

TARGET TEMPERATURE and CURRENT TEMPERATURE

During the actual roasting process the time display will countdown the remaining time in the roast.

If the Select arrow is used to choose the time display it becomes encircled (shown to the left). The remain-

ing time can now be modifi ed by adding or subtracting time using the Chevron up and down arrows. At

any point in the roast, if the time display reaches 00:00 the KN-8828B will automatically eject the beans.

When the display is not encircled (above right) the display will still show the amount of time remaining in

the current roast. The Target Time can be changed at any time during the roast. The total roast time (time

elapsed + time remaining) cannot exceed 25:00. When the Target Time is selected, the Up Chevron arrow

will not be available if 25:00 would be exceeded by the addition of more time.

During the roast, the temperature display can show two different parameters. If the Select arrow is

used to choose the temperature display it becomes encircled (shown to the left). This is the Target Tem-

perature which, if reached, will automatically eject the beans. When the display is not encircled (above

right) it is the current temperature in the roasting chamber. The Target Temperature can be changed at any

time during the roast up to the maximum of 428 F. If the Target Temperature is lowered to the point that it

equals the current temperature the beans will be ejected.

RANGE OF CONTROL ADJUSTMENTS

Target Temperature

167 to 428 F.

Target Time

10:00 to 25:00

Main Fan Speed

Five speeds. Each of the four bars represent 25%. When no bars are showing the fan is off.

Heating Element Power

Eleven selectable heating levels. Each bar represents 10% of the heating element’s

power. When no bars are selected the heating element is off.

SELECTING TEMPERATURE MEASUREMENT UNITS

The KN-8828B Coffee Roaster can be set to display temperatures in Fahrenheit or Celsius. To change

the displayed units follow these steps. This only needs to be done once unless you desire to change the

standard in the future.

NOTE:

Throughout the following step-by-step sections,

black and yellow high-

lighted words refer to the button selections on the control panel of the same name:

With the KN-8828B unplugged, press and hold the

SELECT button (3rd but-

ton from the top).

While holding the

SELECT button in, plug the power cord into an appropriate outlet. Hold

the button for about three additional seconds. The machine will give a quick double-beep. You

can now release the

SELECT button.

The display will show the temperature standard. Change it by using

the

CHEVRON arrow keys. The choices are either “C” for Celsius or

“F” for Fahrenheit.

When the preferred temperature standard is displayed, press

EJECT.

1

2

3

4

Advertising
This manual is related to the following products: