KEYENCE DL-EP1 User Manual

Page 41

Advertising
background image

3-3 Cyclic communication

3-11

3

Communi

cat
in

g wit

h the

IL Seri

es

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -

Parameter List

Current

Value 1

(Unassigned)

108

ID Number 1 (Current Value 1) (32-bit signed integer)

109
110
111

:

:

164

ID Number 15 (Current Value 1) (32-bit signed integer)

165
166
167

Name

Address

(Byte)

bit7

bit6

bit5

bit4

bit3

bit2

bit1

bit0

Item

Description

DL-EP1 Error

Status

The error status of the DL-EP1 is output.
„

ON: An error occurred.

„

OFF: No error occurred.

Warning Status

(Unassigned)

Error Status

The error status of the DL-EP1 or the error statuses of all the connected sensor

amplifiers are output.

When ON, a value is stored in "Error ID Number" and "Error Code". When OFF, 0

is stored in "Error ID Number" and "Error Code".
„

ON: An error occurred in the DL-EP1 or in any of the connected sensor

amplifiers.

„

OFF: No error occurred in the DL-EP1 or in the connected sensor amplifiers.

Sensor Error Status

The target ID number bit of the sensor amplifier where the error occurred is

output.
„

ON: An error occurred in the sensor amplifier with the target ID number.

„

OFF: No error occurred in the sensor amplifier with the target ID number.

Sensor Warning

Status

(Unassigned)

Current Value n

Over Range

(n: 0 to 1)

The current value n (n: 0 to 1) of the sensor amplifier with the target ID number

is compared with the measurement upper limit and the comparison result is

output.
„

ON: The current value n (n: 0 to 1) of the sensor amplifier with the target ID

number is greater than the measurement upper limit.

„

OFF: The current value n (n: 0 to 1) of the sensor amplifier with the target ID

number is less than the measurement upper limit.

(* The current value 1 does not exist in the IL Series.)

Current Value n

Under Range

(n: 0 to 1)

The current value n (n: 0 to 1) of the sensor amplifier with the target ID number

is compared with the measurement lower limit and the comparison result is

output.
„

ON: The current value of the sensor amplifier with the target ID number is less

than the measurement lower limit.

„

OFF: The current value of the sensor amplifier with the target ID number is

greater than the measurement lower limit.

(* The current value 1 does not exist in the IL Series.)

Current Value n

Invalid

(n: 0 to 1)

The status of current value n (n: 0 to 1) of the sensor amplifier with the target ID

number is output.
„

ON: The current value of the sensor amplifier with the target ID number is

invalid.

„

OFF: The current value of the sensor amplifier with the target ID number is

valid (normal).

(* The current value 1 does not exist in the IL Series.)

Advertising