Configuring message communication – KEYENCE DL-EP1 User Manual

Page 53

Advertising
background image

3-4 Message Communication

3-23

3

Communi

cat
in

g wit

h the

IL Seri

es

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -

The following settings are required to execute message communication with the DL-

EP1.

[DL-EP1]

The DL-EP1 does not require any setting.

[Scanner]

Set the applicable service, Class ID, Instance ID, Attribute ID, and service data, and

send the commands used for message communication.

"Objects and Services"

(Page 3-26)

Refer to the scanner manual for details on the setting methods and applicable

commands.

The following lists the contents that can be executed by message communication

when the objects (DL Object) and services unique to the DL-EP1 are used.

(1) Reading data from a sensor amplifier

(2) Writing data to a sensor amplifier

(3) Issuing operation commands to a sensor amplifier

(4) Locking sensor amplifier operations

(5) Reading the number of decimal places from a sensor amplifier

(1) Reading data from a sensor amplifier

Message communication reads parameters from the DL-EP1 and the sensor

amplifier connected to the DL-EP1.

"(1) Reading parameters from a sensor amplifier" (Page 3-48)

Configuring Message Communication

Actions which can be Completed with Message Communication

Command

Response:
1235

IL

Judgment values

(P. V. values): 1235

DL-EP1

Scanner

<Details of command>
Service code: 0EH
Class ID: 67H
Instance ID: 01H
Attribute ID: 0325H (805)

IL

Advertising