- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -

3-4 Message Communication

3-42

3

Communi

cat
in

g wit

h the

IL Seri

es

Group3

0369H

(873)

System

parameter

settings

*6

Set up system parameter.

To reflect the setting, you need to send

"System parameter set request" (0306H (774))

operation command after writing the setting.

Use 0338H (824) to check the system

parameter with which the sensor amplifier is

operating.

bit 0:

0: NPN

1: PNP

bits 1, 2 and 3 (For main unit only. Fixed to

000 for expansion unit)

000: Analog output OFF

001: 0 to 5V

010: -5 to 5V

011: 1 to 5V

100: 4 to 20mA

R/W

DINT

036AH

(874)

Tolerance

tuning -

tolerance

setting range

Set up setting range for tolerance tuning.

Parameter range: 0.000 to 99.999

R/W

DINT

036BH

(875)

Calibration

function

Set up calibration function.

Parameter range: 0 to 1 (initial value: 0)

0:Initial state

1:User setting

R/W

DINT

036CH

(876)

Calibration

function SET1

*2

Set up target value of 1st point for calibration.

Parameter range: -99.999 to 99.999 (initial

value: 0.000)

R/W

DINT

036DH

(877)

Calibration

function SET2

*2

Set up target value of 2nd point for calibration.

Parameter range: -99.999 to 99.999

(initial value: +5.000)

R/W

DINT

036EH

(878)

Calculated

value

calibration

function

*9

Set up calculated value calibration function.

(Main unit only)

Parameter range: 0 to 2 (initial value: 0)

0:Initial state

1:Calculated 2-p calibration

2:Calculated 3-p calibration

R/W

DINT

036FH

(879)

Calculated

value two-point

calibration

function SET1

*2, *9

Set up target value of 1st point for calculated

value two-point calibration. (Main unit only)

Parameter range: -99.999 to 99.999

(initial value: +5.000)

R/W

DINT

0370H

(880)

Calculated

value two-point

calibration

function SET2

*2, *9

Calculated value two-point calibration function

SET2 (Main unit only)

Parameter range: -99.999 to 99.999

(initial value: +10.000)

R/W

DINT

0371H

(881)

Calculated

value three-

point calibration

function SET1

*2, *9

Set up target value of 1st point for calculated

value three-point calibration. (Main unit only)

Parameter range: -99.999 to 99.999

(initial value: +5.000)

R/W

DINT

0372H

(882)

Calculated

value three-

point calibration

function SET3

*2, *9

Set up target value of 3rd point for calculated

value three-point calibration. (Main unit only)

Parameter range: -99.999 to 99.999

(initial value: +10.000)

R/W

DINT

0373H

(883) to

037FH

(895)

(Reserved for system)